Loading...
HomeMy WebLinkAboutORD 2024-36 - Northwest corner of SH130 & CR152 ZoningORDINANCE NO. ,'Z 0 Z Q `3� AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF GEORGETOWN, TEXAS, AMENDING PART OF THE OFFICIAL ZONING MAP TO REZONE 10.418 ACRES IN THE JOHN BERRY SURVEY NUMBER 3, ABSTRACT 51, GENERALLY LOCATED AT THE NORTHEAST CORNER OF STATE HIGHWAY 130 AND COUNTY ROAD 1529 FROM AGRICULTURE TO A PLANNED UNIT DEVELOPMENT WITH A BASE ZONING DISTRICT OF INDUSTRIAL; REPEALING CONFLICTING ORDINANCES AND RESOLUTIONS; INCLUDING A SEVERABILITY CLAUSE; AND ESTABLISHING AN EFFECTIVE DATE. WHEREAS, an application has been made to the City for the purpose of amending the Official Zoning Map, adopted on the 12th day of June, 2012, for the specific Zoning District classification of the following described real property ("The Property"): 10.418 acres in the John Berry Survey No. 3, Abstract 51, generally located at the northeast corner of State Highway 130 and County Road 152, as recorded in Document Numbers 2021183164 and 2021183169 of the Official Public Records of Williamson County, Texas, hereinafter referred to as "The Property"; and WHEREAS, public notice of such hearing was accomplished in accordance with State Law and the City's Unified Development Code through newspaper publication, signs posted on the Property, and mailed notice to nearby property owners; and WHEREAS, the Planning and Zoning Commission, at a meeting on May 21, 2024, held the required public hearing and submitted a recommendation of approval to the City Council for the requested rezoning of the Property; and WHEREAS, the City Council, at a meeting on June 11, 2024, held an additional public hearing prior to taking action on the requested rezoning of the Property. NOW THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF GEORGETOWN, TEXAS, THAT: Section 1. The meeting at which this ordinance was approved was conducted in compliance with the Texas Open Meetings Act, Texas Government Code, Chapter 551. Section 2. The facts and recitations contained in the preamble of this ordinance are hereby found and declared to be true and correct and are incorporated by reference herein and expressly made a part hereof, as if copied verbatim. Ordinance Number: OZ'-1,-,7AP Pagel of 3 Description: Capita 152 PUD Date Approved: June 25, 2024 Section 3. The City Council hereby finds that this Ordinance implements the vision, goals, and policies of the Georgetown 2030 Comprehensive Plan and further finds that the enactment of this Ordinance is not inconsistent or in conflict with any other policies or provisions of the 2030 Comprehensive Plan and the City's Unified Development Code. Section 4. The Official Zoning Map, as well as the Zoning District classification for the Property is hereby amended from the Agriculture Zoning District to the Planned Unit Development Zoning District with a base zoning of Industrial, in accordance with the attached Exhibit A (Location Map) and Exhibit B (Legal Description) and incorporated herein by reference. Section 5. All ordinances or resolutions that conflict with the provisions of this ordinance are hereby repealed, and all other ordinances or resolutions of the City not in conflict with the provisions of this ordinance shall remain in full force and effect. Section 6. If any provision of this ordinance, or application thereof, to any person or circumstance, shall be held invalid, such invalidity shall not affect the other provisions, or application thereof, of this ordinance, which can be given effect without the invalid provision or application, and to this end the provisions of this ordinance are hereby declared to be severable. Section 7. The Mayor is hereby authorized to sign this ordinance and the City Secretary to attest. This Ordinance shall become effective and be in full force and effect immediately in accordance with the provisions of the City Charter of the City of Georgetown. PASSED AND APPROVED on First Reading on the 11t' of June 2024. PASSED AND APPROVED on Second Reading on the 2511 of June 2024. CITY,OF GYORGETOWN, TEXAS JoklIScAroeder, Mayor ATTEST: Ro yen ADe smore, City Secretary APPROVED AS TO FORM: kye asson, bty Attorney Ordinance Number: Page 2 of 3 Description: Capita 152 PUD Date Approved: June 25, 2024 EXHIBIT A rhmrrol, EXHIBIT B Professional Land Surveying, Inc. Surveying and Mapper 10.418 ACRES JOHN BERRY SURVEY NO. 3. ABSTRACT NO, 51 WILLIAMSON COUNTY, TEXAS 3 +0 F:::uh Lunt Au^hn Tr ns 00?q,1 A DESCR]PTION OF 10.418 ACHF,S (APPROXIMA f Fl.'Y 453,820 SCE. F T.) CUT OF THE JOHN BERRY SURVEY NO. 3, ABSTRACT NO. 51 IN WiLLIAMSON COUNTY, TEXAS, 131:INO ALL OF A 5,675 ACRE TRACT CONVEYED TO CAPITA 152 LLC IN A GENERAL WARRANTY DATED NOVEMBER 30, 2021 AND RECORDED IN DOCUMENT NO, 2021 18316i4, AND ALL OF A 1.741 ACRE TRACT CONVEYED TO CAPITA 152 LLCM IN A GENT RAI WARRANTY DATED NOVEMBER 30, 2021. AND RECORDED 1N DOCUMENT MO. 2021183169, BOTIA OF THE OFFICIAL PUBLIC RKORDS OF WILLIAMSON COUNTY, TEXAS; SAID 10.418 ACRES BEING MORE PARTICULARLY DESCRIBED BY METES AND BOUNM AS FOLLOWS - BEGINNING at a 51S' rebar wb 2' Aluminum TX DOT cap found for the southeast owner of said 8-678 acre tract, being a southwest corrapf of a 46.341 acre IrArt de rri l in Document No. 2022412�27 of the Official Public Records of Williamson County, Texas, being in the north right-of-way fine of County Road 1' 2 (riglit-of-way wvrlh varies) as shown on RC;SJ 0440-05-007 and in Document No. 2004077757 of the Official Public records of W111amson Cowity, Texas; THENCE with the south line of the 8.678 acre tract, being the north right -of --way line of County Road 152, the follywing throe (.i) nourser. arKI distarinew 1 South 65°13'17" West, a distance o' 39T.67 feet to a 112" rebar with "SNS 512- 335-3944z cap found 2. North 21'40'23" West" a &staance of 133.94 feet to a 112� rebar found; 3. South 68°23'09" West. a distance of 187.16 feet to a 1;2" rebar w4h "SNS 512- 335-3944' cap found for the intersection of the north right-of-way lino of C ounly Roar[ 152 and the east rightrof•way line of State Highway 130 (right,of-way with varies) as shaven on RCSJ 0 40-Cry-UU7 and In D o mon1 Na-A. 2f1p403gI39C-, 2OD4073311. and 2D04077757, all of the Official PUNic Records of V411lanison County, Texas; THENCE North 32°55'09" West with the west [Inc of the 8.678 acre tram, beinj the east right-of-way fare of State Highway 130, a distance of 19.73 feet to a 54' rebar with 2" Aluminum TXDOT cap found for an angle point In 1hra wokil line of ttre S.678 acre tract, being the south corner of said 1.741 acre tract; 2077-Dll RASE Page 2 j,7 2 THENCE Borth 32o-32'12" West, cons nuing with thy: uast jiglit-cif-way lino Uf State 1119li-wayr 131D, i"nq the west Line of the 1.741 acre tract, a distance of 894.46 feet to a 518' reb.rwith 2" Aluminum TX DOT cap fowid for the wosl (x)iriHr of She 1 741 arse Tract, being an angle point of the 46.39 acre tract also being an angle point in the east right-of- way line: of State Hightvay 130. THENCE North 75`56'17" Fast, with the north lade of the 1.74 :, acre tract, being a scWth line of the 46.39 acre tract, a distance of 178.48 feet to a 5 B' reCar found for the r�arth corner of than 1.741 acre tract, baing tha rturthwekt Qcarrwr cif the 8.680 acre tract, also being an angle point in the south line of the 46.39 acre tract', THENCE with 11te north and riorlli-oasl Imes cif the 8,690 acre tract, being the south and southyvest lines of the 46.313 acre tract. the folloMing Four (4) coijrses and disiaitraw 1 North 76112'1 1" East, a rii%tance of 108.76 feet to a W8 rebar found; 2. South 64°50TT' East, a distance of 231-25 fit 1c a WW rehar founds, 3 South 52'5546" East, a distance of 253.06 feet to a 1 /2' robar found; 4. South 38"57'04" East, a distance of 614.54 feet to the POINT Of BEGINNING of herein described tract containing 10.418 acros of land, more or Wss. Surveyed on the gtdund December 7, 2023. Bearing basis: The Texas Coordinate Syrstern of 1983 (NAD83) (2011). Genital Zone (4203), based on GPS solutions from the local Feat Time Netvmrk (RTN). Attachrr�ents. 2077-001-BASI- 't lAli ..cri I1J R'. U f Y John L. Briley Regiatered Professional Land Surveyor State -of Texas No. 7070 y � '3 T.B.P,E.L.S. Firm No. 10124500 2077-001-BASE EXHIBIT C Capita 152 Planned Unit Development Development Plan Exhibit A A. Property The Capita Planned Unit Development is located on the northeast corner of SH 130 Toll and CR 152. It consists of 10.418-acres described in Exhibit B. herein referred to as the "Property." B. Purpose & Intent The proposed Capita 152 Planned Unit Development (PUD) will serve the growing demand for economic based regional and national businesses needing to take advantage of direct access to the Interstate and Highway systems. Capita 152 PUD will not only create jobs but provide location opportunities for important service users supporting the local community, while also enhancing the City's tax base and reducing employment locating to neighboring communities. Overall, the project's goal is to keep more residents working and spending money in the City of Georgetown. The purpose of the PUD is to establish standards for the development that will fit well within the existing context of its surroundings while still taking advantage of the Employment Center established around it in the 2030 Plan. Modifications to the development standards will ensure that only uses appropriate for the location of the Property are permitted, and that the quality of view from the SH 130 gateway corridor is enhanced. In accordance with UDC Section 4.06.010.0 "Development Plan required", this Development Plan titled Exhibit A is a summary of the development and design standards for the property. B. Applicability and Base Zoning All development of the property shall conform to the base zoning district of Industrial (IN) as shown in Exhibit C. Except for those requirements specifically deviated by this Development Plan, all development standards established in the most current version of the UDC at time of development shall be applicable, including amendments or ordinances adopted after the date of this PUD. In the case that this Development Plan does not address a specific item, the City of Georgetown UDC and any other applicable Ordinances shall apply. In the event of a conflict between the regulations of this PUD and the regulations of the zoning district, the PUD shall control. C. Conceptual Lan Plan. A Conceptual Land Use Plan has been attached to this Development Plan as Exhibit B that illustrates the land use and design intent for the property. The Conceptual Land Use Plan is intended to serve as a guide to illustrate the general vision and design concepts and is not 1IPage intended to serve as a final document. Approval of this PUD, Development Plan, and Conceptual Land Use Plan does not constitute approval of a Site Development Plan per Section 3.09 of the UDC. E. Land Uses The intended uses for the property encompass a combination of light industrial activities, complemented by supporting business park functions tailored for small enterprises with distribution tended as a secondary and supporting use. Exhibit D includes a list of permitted and prohibited uses within the property as described below. 1. Uses Permitted by Right ("P" ). 2. Uses Permitted with Limitations ("L"). These uses may be permitted provided that it meets additional standards referenced in the far right "Note" column of the table 3. Uses Permitted with Special Use Permit ("S"). These uses may be permitted subject to approval of a Special Use Permit by the City Council. Uses that require a Special Use Permit must also comply with the additional standards referenced in the far right "Note" column of the table; and 4. Prohibited Uses F. Dimensional Standards 1. The Dimensional Standards of UDC Table 7.02.020 shall be applicable to the property as outlined in Table F.1 below: Table F.1 Dimensional Standards Table F.1 Dimensional Standards PUD District size min. acreage — Lot width, minimum feet 50 ft. Front/street SH 130 setback min. feet 25 ft. Front/street CR 152 setback, min. feet 50 ft. Side setback, min. feet 10 ft. Side setback to residential district or an existing single- family home in the ETJ that is platted or planned for residential use on the Future Land Use Map,min. feet 35 ft. Rear setback, min. feet 10 ft. Maximum Building Height 60 ft. Maximum Building Size 100,000 SF 2 1 P a g e G. Architectural and Building Design Standards. The Architectural and Building design standards shall be in accordance with the requirements set forth in Section 7.03 of the UDC except where varied here for properties in zone B. Properties in zone A shall be in full compliance with the UDC. I. UDC Sec. 7.03.040.D. Roof Treatments. 1. Parapets shall be used on all flat roofs and meet the following minimum requirements: a. Parapet and or mechanical screen heights will be determined in order to provide full screening of mechanical equipment located on the 11/4" per foot sloped roof from view of adjacent properties at the shared property line and centerline of adjacent right of ways. b. Parapets shall require cornice detailing. Coping cap is an acceptable cornice treatment, example provided in Exhibit E. C. II. UDC Sec. 7.03.040 E. Primary Entrances. Primary entry shall incorporate at least two (2) or more of the following: a. Recessed entrance, projection, parapets, raised corniced parapet over entry, canopy, portico, arched, peaked roof with arcade, integral planters or enhanced glazing. 31Pap,( IV. UDC Sec. 7.03.050.C.1.a - Building Articulation. Horizontal Articulation (Footprint). a. No Building Walls shall extend laterally for a distance greater than three times the building's average height without horizontal articulation consisting of overlapping tilt wall panels. The overlap thickness may vary subtly on the thickness of the tilt wall panel. b. The street -facing aspect of the buildings will feature three main entrances strategically placed to enhance visual appeal and break up the expanse of walls. V. Sec. 7.03.050.C.2. - Building Articulation --Vertical Articulation (Elevation). a. No Loading Dock Walls shall extend laterally for a distance greater than three times the building's average height without vertical articulation consisting of a vertical elevation change of at least 24" in order to prevent a continuous parapet roof line. No Non -Loading Dock Walls shall extend laterally for a distance greater than three times the building's average height without vertical articulation consisting of a vertical elevation change of at least 24" in order to prevent a continuous parapet roof line. b. The change in elevation shall extend laterally for a distance equal to at least seventy-five percent (75%) of the building's average height on Non -Loading Dock Walls. VI. Sec. 7.03.050. D. Architectural Features. 1. In addition to the horizontal and vertical articulation requirements, all building walls shall incorporate at least three of the following architectural features: a. canopies at main tenant entrances, clerestory windows, variation in reveal patterns and colors, form liner cast into concrete panels to form relief, brick and/or stone cast or applied to face of wall panels, or canopy over dock doors or other similar building element features as approved by the Director or their designee, an example is provided in Exhibit E. H. Landscaping 1. The "Street Yard Landscaping" standards of UDC Section 8.04.030 shall be modified so that the shade trees required in the street yard along CR 152 must be designed as street trees on an average of 20-feet on -center along the entirety of the property line. 2. A screening barrier, consisting of a 6-foot berm, will be strategically established between the sidewalk along CR 152 and the building. Furthermore, the detention area will be positioned between the berm and the building, complemented by the planting of trees to enhance screening along the sidewalk. I. Loading 1. No loading docks shall be installed on walls facing a public street or visible from a public street. K. Impervious Cover & Stormwater 4 1 P a g e 1. The development within the PUD will comply with the impervious cover limitation established in UDC Section 11.02, however, a maximum amount of 70% impervious cover may be permitted through the use of the impervious cover waivers established in UDC Section 11.02.020. L. PUD Modifications In conformance with Section 4.06.010.D. 3 of the UDC, modifications to this Development Plan shall require City Council approval of an amendment to this PUD processed pursuant to Section 3.06 of the UDC, except, where the Director of Planning determines such modifications to be minor, the Director may authorize such modifications. Minor modifications may include changes to building sizes, uses, or locations providing those modifications conform to the general intent of this PUD, uses authorized by this PUD, or to applicable provisions of the UDC and any other applicable regulations. List of Exhibits Exhibit A — Development Plan Exhibit B — Field Notes Exhibit C — Conceptual Plan Exhibit D — Land Use Chart Exhibit E — Landscape Exhibit Exhibit F - Renderings 5 1 P a g e SVX31 'NM01308030 ?M 80 V 0% HS NVId 311S kHVNIV41138d q < and M VIldVO 34 w Exhibit D — Land Use Chart Specific Use I IN I Correctional Facility I - Parks and Open Spaces Cemetery, Columbaria, Mausoleum or Memorial Park Specific Use IN Sexually Oriented Business — Self Storage, Indoor — Self Storage, Outdoor — Stone, Mulch or Dirt Sales Yards — Manufactured Housing Sales — Automobile Sales, Rental or Leasing Facility _ Fuel Sales — Fuel Sales with more than ten multi -fuel dispensers _ Car Wash — Recreational Vehicle Sales, Rental or Service _ Towing Services and Impound Lots — Specific Use IN Truck Terminal — Lumber Yard — Dry Cleaning or Laundry Plant — Asphalt or Concrete Batch Plant — Resource Extraction — Oil Refinery and Distribution — Recycling Collection Center — Waste Related Uses — Wrecking, Scrap or Salvage Yard — Outdoor Storage L Specific Use IN Meat Market — 10IPage Taxidermist Specific Use IN Concrete Products, Temporary — Construction Field Office — Construction Staging, Off -site — 111Page Exhibit E — Landscape Exhibit to " OC TREESI SHURW HY BERM SCREENING DETENTION AREA SECTION THRU DETENTION AREA 1 I IIj I?BFRMS 1 PROPOSED 163' — -1 TREE BUFFER j r� PROPOSED a — � STORY WATER ' DETENT-ON 1 I— AREA IJ s PROPOSED 4110 — 1 BUILDING B I rWIM. 50,041 SF _SPACE J 'wit JT 11 I I :I I I 1111. 68 PARKING. SPACES / r llllli.11I.111] t r •' tie IEU¢;K N 19.54' PROJECT DATA: SITL 10.417 ACRES BUILDING A: 50,011 SF PARKING: 108 SPACES (2 15/1,000 SF) BUILDING B: 5O.W SF PARKING: 103 SPACES (2 06/1.000 SF) Z J N a aaLox W N F- F- �n��z r— } 00 cc 0 Q ¢ o h uj 3 o Q LLJ W U Q- R✓®�1 noire � — PRELIMINARY SITE PLAN 'TRILL DUFFER CONSISTS OF AO1 CITY APPROVED TREES TO REACH 10' AVERAGE MATURE HEIGHT OR GREATER s 121 Page C a IrL1�MJ �_ ■ r � I. UDC Sec. 7.03. 040.D. Roof Treatments. LB. 141 P Az, x dz rc �o� + I EE I 1 Ec 0 w p o p p N U w � U � W U O O d � JJ Q 3 Y1i •0-'S _ .0-.I I a ti 0 ZaI� � U W Q W O W � 1 � fn � N � J v an Ln rq VI. Sec. 7.03.050. D. Architectural Features. LA. 161Pjii,e