Loading...
HomeMy WebLinkAboutRES 042324-5.F - ROW AddendumRESOLUTION NO. 042 3- 'LA - 5. F AN RESOLUTION OF THE CITY COUNCIL OF THE CITY OF GEORGETOWN, TEXAS, ADOPTING ADDENDUM NO. 1 TO THE CITY OF GEORGETOWN RIGHT-OF-WAY REGULATIONS UNDER CHAPTER 12.08 OF THE CODE OF ORDINANCES; REPEALING CONFLICTING RESOLUTIONS; INCLUDING A SEVERABILITY CLAUSE; AND ESTABLISHING AN EFFECTIVE DATE. WHEREAS, the City Council has determined that establishing regulations related to microtrenching within the City Right -of -Way will help encourage continued development of fiber services within the City; and WHEREAS, the City adopted Right -of -Way Regulations on October 27, 2020 pursuant to Chapter 12.08 and provided that the Right -of -Way Regulations may be amended by Resolution of the City Council; and WHEREAS, the City Council finds that adopting the Addendum No. 1 "Microtrenching" will be in the best interest of the public, as set out herein. NOW THEREFORE BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF GEORGETOWN, TEXAS: Section 1. The meeting at which this resolution was approved was conducted in compliance with the Texas Open Meetings Act, Texas Government Code, Chapter 551. Section 2. The facts and recitations contained in the preamble of this resolution are hereby found and declared to be true and correct and are incorporated by reference herein and expressly made a part hereof, as if copied verbatim. Section 3. Addendum No. 1 "Microtrenching" attached hereto as Exhibit A is hereby adopted. Section 4. All resolutions that conflict with the provisions of this resolution are hereby repealed, and all other resolutions of the City not in conflict with the provisions of this resolution shall remain in full force and effect. Section 5. If any provision of this resolution, or application thereof, to any person or circumstance, shall be held invalid, such invalidity shall not affect the other provisions, or application thereof, of this resolution, which can be given effect without the invalid provision or application, and to this end the provisions of this resolution are hereby declared to be severable. Resolution Number: OLI Z3 Zu - .5 F Page 1 of 2 Subject: Microtrenching Policy Addendum Date Approved: ��,\ 23iUVA Section 7. The Mayor is hereby authorized to sign this resolution and the City Secretary to attest. This resolution shall become effective and be in full force and effect immediately in accordance with the provisions of the City Charter of the City of Georgetown. PASSED AND APPROVED on the 1-of +�_, 2024. ATTEST: OF GEORGETOWN: Robyn De smore, City Secretary osh Schroer, Mayor APPROVED AS TO FORM: d,4 Skye sson, City Attorney Resolution Number: lDxk ts 24' 5. F Page 2 of 2 Subject: N icrotrenching Policy Addendum Date Approved: Z-3 1 Z004 CITY OF GEORGETOWN RIGHT-OF-WAY REGULATIONS ADDENDUM NO. 1 M ICROTRENCH I NG Dated: April 18, 2024 Adopted: April 23, 2024 Effective Date: April 24, 2024 This Addendum No. 1 to the City of Georgetown Right -of -Way Regulations is adopted pursuant to the City's police power and pursuant to Chapter 12.08 of the Code of Ordinances for the purpose of establishing standards and procedures to ensure that persons who engage in microtrenching within City owned Right -of -Way. These microtrenching regulations apply to any proposed microtrenching work in City Right -of -Way. To the extent that a conflict exists between the microtrenching specific regulations contained in this Addendum and the current effective City Right -of -Way Regulations, the regulations in this Addendum shall supersede. All Right -of -Way Regulations not in conflict shall continue to apply, and all defined terms in this Addendum shall have the meaning given in the Right -of -Way Regulations. In addition, these regulations shall not conflict with, and do not supersede, the most current edition of the Construction Standards and Specifications Manual with regards to microtrenching. Definitions "Microtrenching" shall mean a Construction Activity used to install underground broadband internet networks, involving placing conduits and fiber optic cables in a shallow slot trench. Microtrenching Standards The Permit Holder shall microtrench based the standards below and as shown on the attached Standards and Specifications (Exhibit A). 1. Minimum Offset of Trench in Street from Face of Gutter — Zero (0) inches 2. Maximum Offset of Trench in Street from Face of Gutter — 36 inches 3. Number of Trenches Per Side of Street — Three (3) (each) 4. Maximum Width of Trench — Two and a half (2.5) inches 5. Minimum Depth of Trench in Residential/Collector Streets - Six (6) inches 6. Maximum Depth of Trench in Residential/Collector Streets —14 inches 7. Minimum Depth of Trench in Arterial Streets —10 inches 8. Maximum Depth of Trench in Arterial Streets —16 inches Asphalt repair 1. First installed microtrench at face of gutter— Flowable backfill topped with asphaltic sealer 2. Second installed microtrench at 18 inches from gutter—flowable fill, topped with two (2) inch thick asphalt pavement, 18" wide, centered over trench. 3. Third installed microtrench at 36 inches from gutter —flowable fill, topped with two (2) inch thick asphalt pavement, 18" wide, centered over trench. 4. Street crossings - flowable fill, topped with two (2) inch thick asphalt pavement, 18" wide, centered over trench. Microtrenching is not permitted in the following areas unless approved in writing by the City Concrete streets, driveways, sidewalks, curb and gutter, aprons, or other concrete structures. Special pavements such as, decorative paving, bricks, concrete pavers, exposed aggregate Concrete, stamped asphalt, or other unique non- concrete or non --asphalt materials. 4. Streets that are within their one year warranty post -construction 5. Crown of the street intersection LEGEND RIGHT OF WAY (TYP) FACE OF CURB (TYP) EDGE OF PAYMENT (TYP) PROPOSED MICROTREN FLOWABLE BACKF SEE NOTE 5.4 PREFERRED STREET CROSSING PATHWAY IF MORE THAN 2' HORIZONTAL CLEARANCE FROM EXISTING APPURTENANCES. TYP FOR ALL ALIGNMENTS ALTERNATE STREET CROSSING PATHWAY IF PREFERRED PATHWAY IS LESS THAN 2' HORIZONTAL CLEARANCE FROM EXISTING APPURTENANCES. TYP FOR ALL ALIGNMENTS ROADWAY WITH VALLEY GUTTER & APRON @ CURB RETURN NOTE: REFER TO MICROTRENCH DETAILS ASPHALTIC SEALER SEE NOTE 6 EXISTING ASPHALT PER CITY STANDARD (DEPTH VARIES) - FUTURE MICROTRENCH SECTION A -A FIRST INSTALLED MICROTRENCH NEW ASPHALT PAVEMENT MICROTRENCH PATHWAY (TYP) RIGHT OF WAY (TYP) FACE OF CURB (TYP) • • 'I' y60, ROADWAY WITH CURB AND GUTTER @ CURB RETURN NOTE: REFER TO MICROTRENCHING DETAILS NOTES TACK COAT ALL EDGES EXISTING ASPHALT PER CITY STANDARD (DEPTH VARIES) FLOWABLE BACKFILL SEE NOTE 5.4 1.5' B.1 EXISTING FUTURE MICROTRENCH MICROTRENCH SECTION A -A SECOND INSTALLED MICROTRENCH TABLE 1: MICROTRENCH DIMENSIONS STREET TYPE: RESIDENTIAL/COLLECTOR MICROTRENCH DIMENSIONS A.1 I A.2 A.3 B.1 I B.2 B.3 I CA C.2 I C.3 I D.1 D.2 D.3 INCHES WIDTH OF TRENCH MAX 2.5 MAX 2.5 MAX 2.5 MAX 2.5 MINIMUM DEPTH OF COVER 6 6 6 12 MAXIMUM DEPTH OF TRENCH 10 14 14 16 12/19/2023 ���� F-312 IS OF rF �� i yip .•..........•.�s111 ' 1 ........... . / JOSEPH S. ROBERTS X ' 'C'EN5F;�•••V���i S'/ONA� ��- ■ ■ ■ h a Lff 13620 BRIARWICK DR., SUITE 100 AUSTIN, TEXAS 78729 TEL. (512) 777-4600 ® ASPHALT PAVEMENT 0 CONCRETE PAVEMENT ® SUBGRADE FLOWABLE BACKFILL CONDUIT ZONE MICROTRENCH PATHWAY - - - PREFERRED STREET CROSING PATHWAY - - - ALTERNATE STREET CROSSING PATHWAY ® APPURTENANCE (UTILITY VARIES) ® HANDHOLE ® BOREHOLE OR RECEIVING HOLE EXISTING ASPHALT NEW ASPHALT PER CITY STANDARD PAVEMENT (DEPTH VARIES) 1.5' TACK COAT ALL EDGES fC2 C.3 FLOWABLE BACKFILL SEE NOTE 5.4 3' C.1 EXISTING MICROTRENCH SECTION A -A THIRD INSTALLED MICROTRENCH TABLE 2: MICROTRENCH DIMENSIONS STREET TYPE. ARTERIAL MICROTRENCH DIMENSIONS Al A.2 A.3 B.1 B.2 B.3 CA C.2 C.3 (INCHES) WIDTH OF TRENCH MAX 2.5 MAX 2.5 MAX 2.5 MAX 2.5 MINIMUM DEPTH OF COVER 12 12 12 12 MAXIMUM DEPTH OF TRENCH 16 16 16 16 AGE 0 RG E O RG I=TOW N TEXAS CITY OF GEORGETOWN BROADBAND MICROTRENCHING STANDARDS PROJECT NO.: 45192.002 ISSUED 12/19/2023 DRAWN BY: RS CHECKED BY: JR SCALE: N.T.S. SHEET TITLE: MICROTRENCHING DETAILS 1 PROPOSED NEW ASPHALT PAVEMENT PROPOSED MICROTRENCH MICROTREN SEE NOTE 2.7 FLOWABLE BACKFILL SEE NOTE 2 1 TACK COAT ALL EDGES SEE NOTE 5.4 TACK COAT ALL EDG EXISTING CONCRETE r EXISTING ASPHALT CURB & GUTTER t PER CITY STANDARD (DEPTH VARIES) L D..3 EXISTING SUBGRADE �� 1 CONDUIT ZONE J FUTURE MICROTRENCH SECTION B-B FIRST INSTALLED MICROTRENCH CURB GUTTER SEE NOTE 4 CONDUIT ZONE MAX 2.5" STREET CROSSING MIN COVER SEE NOTE SEE TABLES 1 AND 2 1 SECTION C-C CURB AND GUTTER CROSSING 12/19/2023 �� F-312 .je. of .. �h •f JOSEPH S. ROBERTS i 137860 iOO EXISTING SUBGRP CONDUIT ZG .� NEW ASPHALT PAVEMENT FLOWABLE BACKFILL PROPOSED SEE NOTE 5.4 MICROTREN SEE NOTE 2 NEW ASPHALT PAVEMENT FLOWABLE BACKFILL SEE NOTE 5.4 TACK COAT ALL EDGES EXISTING ASPHALT PER CITY STANDARD (DEPTH VARIES) D.2 EXISTING ASPHALT 1 D 3 PER CITY STANDARD (DEPTH VARIES) '\- FUTURE MICROTRENCH SECTION B-B SECOND INSTALLED MICROTRENCH STREET CROSSING VALLEY GUTTER EXISTING CONCRETE CONTRACTOR SHALL NOT PER CITY STANDARD (DEPTH VARIES) CUT EXISTING REINFORCEMENT OR DOWELING IN VALLEY - - -- -r---- -- GUTTERS ------- ------- MIN COVER SEE TABLES 1 AND 2 SEE NOTE 4 CONDUIT ZONE SECTION D-D' VALLEY GUTTER CROSSING EXISTING MICROTRENCH FIRM EXCAVATION LINE EXISTING UTILITY(S) SECTION B-B THIRD INSTALLED MICROTRENCH STREET CROSSING SAWCUT EDGES TO NEAT, CLEAN, STRAI VERTICAL FACES, TACK COAT ALL EDG LIMIT OF POTH EXCAVATION INSTALL FINISH SURFACE TO MATCH ADJACENT SURFACE. MATCH EXISTING MATERIAL MATCH EXISTING ASPHALT PAVEMENT OR CONCRETE THICKNESS FLOWABLE BACKFILL SEE NOTE 5.4 1-5' MAX POTHOLE REPAIR PROJECT NO.: 45192.002 ISSUED: 12119/2023 ■ ■ DRAWN BY: RS CHECKED BY: MENhaLff CITY OF GEORGETOWN SCALE: N.T.S.N. ' ■ BROAD BAND SHEET MICRCROTRENCHING 13620 BRIARWICK DR., SUITE 100 i�r.'3'K MICROTRENCHING STANDARDS DETAILS AUSTIN, TEXAS 78729 G EORG ETOWN TEL. (512) 777-4600 TEXAS 2 MICROTRENCHING THE FOLLOWING STANDARDS APPLY TO MICROTRENCHING: 1) MICROTRENCHING IS NOT PERMITTED IN THE FOLLOWING AREAS: 1 1 CONCRETE STREETS, DRIVEWAYS, SIDEWALKS, CURB AND GUTTER, APRONS, OR OTHER CONCRETE STRUCTURES. 1.2 SPECIAL PAVEMENTS SUCH AS, DECORATIVE PAVING, BRICKS, CONCRETE PAVERS, EXPOSED AGGREGATE CONCRETE, STAMPED ASPHALT, OR OTHER UNIQUE NON- CONCRETE OR NON -ASPHALT MATERIALS. 13 STREETS THAT ARE WITHIN THEIR ONE YEAR WARRANTY POST -CONSTRUCTION 1.4 CROWN OF THE STREET INTERSECTION 2) MICROTRENCHING MUST: 2.1 ONLY INSTALL TELECOMMUNICATION CONDUIT. 22 HAVE MAXIMUM 2.5 " WIDE TRENCH; 2.3 BE RESTORED WITH PREAPPROVED FLOWABLE BACKFILL 2.4 CONDUITS MUST BE TRACEABLE WITH 14 GAUGE TRACER WIRE MINIMUM; 2.5 WHERE APPLICABLE, CONFORM TO SEPARATION REQUIREMENTS (HORIZONTAL AND VERTICAL) PER THE GEORGETOWN UTILITY SYSTEMS CONSTRUCTION SPECIFICATIONS AND STANDARDS 2.6 BORE OVER OR UNDER TRAFFIC LOOPS WITH A MINIMUM OF 6" CLEARANCE 2.7 BE CONSTRUCTED WITH CONTINUOUS UNIFORM STRAIGHT AND NEAT EDGES 3) LOCATION OF TRENCHES 3.1 MICROTRENCHING IS APPROVED ON RESIDENTIAL, COLLECTOR AND ARTERIAL STREET CLASSIFICATION 3.2 MICROTRENCHING MAY BE UTILIZED ON EACH SIDE OF A STREET. 3.3 MUST BE LOCATED AT THE EDGE OF LIP OF GUTTER OR OFFSET TRENCHES AS SHOWN ON DETAIL (A -A). MAXIMUM THREE (3) TRENCHES PER SIDE OF STREET 3.4 MICROTRENCHING SHALL BE CONSTRUCTED AND PHASED TO MINIMIZE INTERFERENCE WITH VEHICULAR TRAFFIC. 3.5 MICROTRENCHING MAY EXTEND THROUGH AN INTERSECTION AND CONTINUE ADJACENT TO THE CURB ON THE OTHER SIDE OF THE INTERSECTION. 3.6 PRIOR TO MICROTRENCHING OPERATION, THE CITY INSPECTOR AND CONTRACTOR SHALL "WALK" THE MICRO -TRENCHING PATH AFTER TX811 LOCATE MARKS HAVE BEEN COMPLETED THE PURPOSE OF THE "WALK" IS TO IDENTIFY ANY AREAS OF POTENTIAL CONFLICT AND/OR INTERFERENCE AND RECORD THE RESULTS OF THE "WALK". ADDITIONALLY, THE CONTRACTOR SHOULD VERIFY THAT ALL UTILITIES HAVE BEEN LOCATED. THE CONTRACTOR SHALL CROSS-CHECK THE RECORD DRAWINGS AND PLANS WITH FIELD LOCATE MARKS TO DETERMINE DISCREPANCIES. 3.7 A SECOND MICRO -TRENCH MAY BE PLACED 1.5 FEET AWAY FROM THE EDGE OF PAVEMENT. A THIRD MICROTRENCH MAY BE PLACED 3 FEET AWAY FROM THE EDGE OF PAVEMENT 4) PAVEMENT CUTS, VAULTS AND SERVICE CONNECTIONS 41 SAWCUTS SHALL BE STRAIGHT AND CLEAN 4.2 THE VERTICAL FACES OF THE TRENCH MUST BE CLEAN, OIL FREE, WITH NO LOOSE MATERIAL. 4.3 CONTRACTOR SHALL JACK OR PUSH CONDUITS DIRECTLY UNDER THE CURB AND GUTTER AND/OR VALLEY GUTTER. 4.4 CONNECTION TO SERVICE LATERALS, JUNCTION BOXES, ETC., SHALL BE DONE SUCH THAT CURB AND GUTTER IS NOT DISTURBED, SETTLED OR DAMAGED. 4.5 THE USE OF HYDRO -JETTING IS NOT PERM ITTED.TRENCHLESS METHODS SHALL NOT CREATE A VOID TWO TIMES GREATER THAN CONDUIT. VOID SHALL BE COMPACTED AND BACKFILLED WITH APPROVED FLOWABLE FILL. 5) BACKFILL PROCEDURES BACKFILL OF ALL TRENCHES AND BORE PITS SHALL BEGIN IMMEDIATELY FOLLOWING INSTALLATION AND INSPECTION OF THE NEW FACILITY AND SHALL BE IN ACCORDANCE WITH THE FOLLOWING REQUIREMENTS 5.1 TRENCH BACKFILL SHALL BE PLACED IN A TRENCH THAT IS FREE OF STANDING WATER. 5.2 ALL LOOSE CONCRETE OR ROCKS, ROOTS, TRASH AND OTHER DEBRIS SHALL BE REMOVED FROM THE EXCAVATION PRIOR TO ANY BACKFILL BEING PLACED. 5.3 NO SAND BEDDING SHALL BE USED. 5.4 THE BACKFILL MATERIAL (FLOWABLE FILL) MIXTURE SHALL CONSIST OF 188 POUNDS OF TYPE III PORTLAND CEMENT, 94 POUNDS OF FLY ASH AND 3,000 POUNDS OF SAND PER CUBIC YARD OF FLOWABLE BACKFILL. EQUIVALENT FLOWABLE FILL MAY BE SUITABLE WITH APPROVAL OF THE CITY ENGINEER THE MATERIAL MUST ALSO: (A) FREE FLOW TO THE BOTTOM OF THE TRENCH; (B) BE SELF -COMPACTING, SELF -CONSOLIDATING; (C) BE STABLE UNDER TRAFFIC LOADS; (D) BE SUITABLE FOR THE ROAD ENVIRONMENT 12/19/2023 �� F-312 i� OF % l�I p ,........ .,,s 111 o * * 11/ op f JOSEPH S. ROBERTS i 137860 1 0. 17) �C.S.<iCENSEO..G�� �i4Lh ZONAL E?= 5.5 BACKFILL SHALL BE PROPERLY CONSOLIDATED TO PREVENT FORMATION OF AIR POCKETS. 5.6 THE BACKFILL MATERIAL MUST BE 100 % CURED BEFORE THE ASPHALTIC SEALANT IS APPLIED 5.7 DETERMINED THROUGH TESTS OR INSPECTIONS THAT THE BACKFILL DOES NOT MEET THE ABOVE REQUIREMENTS, THE BACKFILL SHALL BE CONSIDERED UNACEPTABLE AND SHALL BE REMOVED AND REPLACED. THE CONTRACTOR SHALL BEAR THE COST OF CORRECTIONS AND SUBSEQUENT TESTING IF THE BACKFILL IS DEEMED UNACCEPTABLE AND/OR THE TRENCH IS BACKFILLED WITHOUT THE TRENCH INSPECTED BY THE CITY INSPECTORS. 6) ASPHALTIC SEALER / OVERBAND THE ASPHALTIC SEALING MATERIAL, ALSO KNOWN AS OVERBAND, PLACED OVER THE TOP OF THE MICRO -TRENCH, SHALL BE CRAFCO'S " MASTIC ONE PART NO.33339" OR MAXWELL PRODUCTS "GAP MASTIC B/ MASTIC D" PRODUCTS. IT SHOULD BE APPLIED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS OR THE REQUIREMENTS OF THIS STANDARD, WHICHEVER IS MORE STRINGENT, INCLUDING ADHERENCE TO THE MANUFACTURER'S SPECIFICATIONS. 6.1 THE SEALANT SHALL BE 1/4" MINIMUM THICK BELOW THE PAVEMENT SURFACE AND OVERLAY THE GROOVE LEAVING A MAXIMUM OVERBAND APPEARANCE OF 3" WIDTH TOTAL CENTERED ON THE EXCAVATION CENTERLINE. 6.2 WHERE THE TRENCH IS ADJACENT TO CURB & GUTTER OR OTHER CONCRETE SURFACE, THE SEALANT SHALL BE 1/4" MINIMUM THICKNESS BELOW THE PAVEMENT SURFACE AND OVERLAY THE GROOVE LEAVING A 3" WIDE OVERBAND ON THE ASPHALT SURFACE. 6.3 THE HEIGHT OF THE SEALANT ABOVE THE PAVEMENT SURFACE SHALL NOT EXCEED 1/8". 6.4 THE RESTORED SURFACE SHALL BE THOROUGHLY COMPACTED, SMOOTH AND TRUE TO GRADE AND CROSS-SECTION. THE RESTORATION SHALL BE DEEMED UNACCEPTABLE IF RUTS, HUMPS, DEPRESSION OR IRREGULARITIES EXIST AND ARE NOT CORRECTED TO THE SATISFACTION OF THE CITY ENGINEER. CORRECTION OF UNACCEPTABLE WORK SHALL BE ACCOMPLISHED WITHIN FIVE (5) WORKING DAYS AFTER NOTIFICATION FROM THE ENGINEER OF THE UNACCEPTABLE WORK 6.5 RESTORATION OF ANY DAMAGED TRAFFIC CONTROL DEVICES MUST BE COMPLETED, INCLUDING BUT NOT LIMITED TO, EMBEDDED LOOP DETECTORS AND PAVEMENT MARKINGS 6.6 DAMAGED LOOP DETECTORS SHALL BE REPLACED THROUGH COORDINATION WITH THE CITY ENGINEER 7) SITE RESTORATION AND POTHOLE REPAIR NOTES 7.1 A "POTHOLE" IS USED INTERCHANGEABLY TO DESCRIBE A SUBSURFACE UTILITY ENGINEERING TEST HOLE OR A VACUUM -EXCAVATED BOREHOLE OR RECEIVING HOLE. 7.2 A CONTRACTOR PERFORMING CONSTRUCTION IN THE PUBLIC RIGHTS -OF -WAY SHALL RESTORE THE PUBLIC RIGHTS -OF -WAY TO A CONDITION THAT IS EQUAL TO OR BETTER THAN THE CONDITION PRESCRIBED IN THIS DETAIL OR OTHER APPLICABLE CITY DESIGN AND CONSTRUCTION STANDARDS. 7.3 CONCRETE DAMAGE, POTHOLE EXCAVATIONS,BORE HOLE EXCAVATIONS, RECEIVING HOLE EXCAVATIONS OR OTHER DAMAGE IN CONCRETE FACILITIES SHALL BE SAWCUT AND REMOVED TO THE NEAREST JOINT. SIDEWALK PANELS MUST BE ENTIRELY REMOVED AND REPLACED, IF DAMAGED OR POTHOLED PER GEORGETOWN UTILITY SYSTEMS CONSTRUCTION STANDARDS AND SPECIFICATIONS. 7.4 LANDSCAPE - SOD SHALL BE USED FOR TURF REPLACEMENT AND SHALL MATCH EXISTING ADJACENT TURF. RUTS SHALL BE REMOVED, AND THE TOPSOIL SHALL BE PREPARED TO PROVIDE A SMOOTH SURFACE FREE OF ROCK AND GRAVEL IRRIGATION SYSTEMS SHALL BE REPAIRED TO PRE-EXISTING CONDITION. 7.5 RESTORATION MUST BE MADE IN A TIMELY MANNER. IF RESTORATION IS UNSATISFACTORY OR NOT PERFORMED IN A TIMELY MANNER, ALL OF THE CONTRACTOR'S WORK ON THE PROJECT WILL BE HALTED, AND NO ADDITIONAL PERMIT WILL BE ISSUED UNTIL THE RESTORATION IS COMPLETED TO THE SATISFACTION OF THE CITY. ANY HOLD ON THE CONTRACTOR'S WORK WILL INCLUDE WORK PREVIOUSLY PERMITTED BUT NOT COMPLETED. 7.6 CONTRACTOR SHALL SCHEDULE A FINAL WALK WITH THE CITY INSPECTOR ONCE CONSTRUCTION IS COMPLETE. THE CITY INSPECTOR WILL "CLOSE OUT' THE PERMIT ONCE HE/SHE ACCEPTS THE WORK AND THE CITY RECEIVES A DATA DELIVERABLE FILE IN .SHP OR .GDB FORMATS WITH LINE DATA ATTRIBUTING THE UTILITY OWNER, INSTALLATION TYPE (AERIAL, BORE, CONDUIT RENTAL, EXISTING, MICRO -TRENCH, NON -CITY RENTAL, OTHER, TRENCH), STATUS (CONSTRUCTION COMPLETE, OTHER, PROPOSED), THE PERMIT NUMBER AND THE DATE OF INSTALLATION 7.7 THE MAXIMUM PAVEMENT CUT FOR SINGLE VACUUM POTHOLE SHALL NOT EXCEED 18"X18". 7.8 CLUSTERED POTHOLES, TWO FEET OF SEPARATION OR LESS, MUST BE COMBINED TO FORM ONE UNIFORM PATCH. CONTRACTOR TO COORDINATE WITH CITY ENGINEER WHEN ASPHALT RESTORATION EXCEEDS 24'X24" 7.9 TEMPORARY PAVEMENT SHALL BE AUTHORIZED FOR TEN BUSINESS DAYS OR AT THE DISCRETION OF THE CITY ENGINEER OR CITY INSPECTOR. 7.10 IN THE EVENT THAT PERMANENT POTHOLES, TEMPORARY POTHOLES OR COMPLETED MICROTRENCHES SETTLE 1/4" DIFFERENCE OR GREATER, THE CONTRACTOR SHALL PERMANENTLY REPAIR THE DEFICIENCIES PER CITY OF GEORGETOWN UTILITY SYSTEMS CONSTRUCTION SPECIFICATIONS AND STANDARDS OR THESE DETAILS WITHIN TWO DAYS. 7.11 THE CONTRACTOR WILL BE REQUIRED TO REMOVE AND RESTORE EXISTING LANDSCAPE AND LANDSCAPE IRRIGATION THAT IS DISTURBED BY CONSTRUCTION. SAD LANDSCAPE AND LANDSCAPE IRRIGATION SHALL BE REPLACED IN -KIND AND REPAIRED TO THE SATISFACTION OF THE PROPERTY OWNER (IF APPLICABLE) AND THE CITY INSPECTOR. EXISTING CONDITIONS DEFINED HEREIN SHALL INCLUDE, BUT NOT LIMITED TO PLANTS, PAVESTONES, ROCK, GRAVEL, DRIVEWAYS, CONCRETE BORDERS, RETENTION BERMS, SPRINKLER SYSTEMS AND OTHER LANDSCAPE MATERIALS. 8) UTILITIES 8.1 THE CONTRACTOR SHALL IDENTIFY ALL UTILITIES, INCLUDING SERVICE CONNECTIONS IN THE FIELD. THE CONTRACTOR SHALL CONTACT TX811 AT LEAST 48 HOURS PRIOR TO START OF WORK AT 8-1-1 OR TOLL FREE AT 1-800-422-4133. THE CONTRACTOR SHALL FURTHER SUPPLEMENT THE FINDINGS OF TXB11 TO DETERMINE THE EXACT LOCATIONS AND DEPTHS OF ALL UTILITIES BY USING A MOBILE GROUND PENETRATING RADAR SYSTEM. THE CONTRACTOR SHALL POTHOLE ALL CROSSING UTILITIES AND PARALLEL UTILITIES WITHIN 18-INCHES OF THE PROPOSED ALIGNMENT TO A DEPTH OF 6-INCHES BELOW THE BOTTOM OF THE MICROTRENCH. TO DETERMINE THE EXISTING UTILITY ALIGNMENT AND AND ELEVATION POTHOLES SHALL BE IMMEDIATELY BACKFILLED AND COMPACTED WITH SPECIFICATIONS OR RESTORED AS DIRECTED BY THE CITY ENGINEER. 8.2 IF EXISTING UTILITIES ARE DAMAGED, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE INSPECTOR. UTILITY OWNER TO PERFORM THE REPAIRS PROMPTLY ACCORDING TO THEIR REQUIREMENTS. 9) GRIND AND RESURFACE SECTION 9.1 COMMENCEMENT OF SURFACE PREPARATION SUCH AS GRINOINGICHIPPING FOR ASPHALT CONCRETE PAVING REPLACEMENT WILL OCCUR NO SOONER THAN 48 HOURS AFTER BACKFILL FILL OF TRENCH. FIELD CONDITIONS OR MATERIAL USED MAY NECESSITATE A LONGER WAIT AS DETERMINED BY THE INSPECTOR OR CITY ENGINEER. 9.2 ASPHALT CONCRETE SHALL BE GROUND AND CAPPED AS SOON AS THE BACKFILL HAS CURED, NOT TO EXCEED 15 CALENDAR DAYS. 9.3 EXISTING ASPHALT CONCRETE AND FLOWABLE BACKFILL SHALL BE GROUND DOWN TO 2" FOR A WIDTH OF 18" BUT NO LESS THAN 6" FROM BOTH EDGES OF THE MICROTRENCH AND RESURFACED WITH CITY STANDARDS 9.4 TACK COAT ALL EDGES IMMEDIATELY BEFORE THE ADJOINING ASPHALT CONCRETE IS PLACED. 9.5 PAVEMENT SHALL MATCH THE EXISTING ROADWAY ELEVATIONS AND PROVIDE A SMOOTH SURFACE. SUBJECT TO ACCEPTANCE BY THE INSPECTOR OR THE CITY ENGINEER. 9.6 ASPHALT FOR PAVING MIXTURE AND TACK COAT SHALL MEET THE REQUIREMENTS OF TEXAS DEPARTMENT OF TRANSPORTATION ITEM 300 OF THE STANDARD SPECIFICATIONS FOR CONSTRUCTION OF HIGHWAYS, STREETS AND BRIDGES. ASPHALTIC MATERIAL SHALL BE APPROVED BY THE CITY OR THE CITY ENGINEER. PROJECT NO.: 45192.002 ISSUED: 12/19/2023 ■ ' DRAWN BY: RS haLffCITY OJR F GEORGETOWN CHECKED BY: N.T.S.SCALE: N. ■ BROAD BAND SHEET TITLE: 13620 BRIARWICK DR., SUITE 100 t`r. ials MICROTRENCHING STANDARDS GT STANDARDS AUSTIN, TEXAS 78729 AGEG E'T""6 N TEL. (512) 777-4600 TEXAS 3