HomeMy WebLinkAboutRES 960711-W - Manufactured Housing P&ZRESOLUTION NO.
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF
GEORGETOWN, TEXAS, PROVIDING GUIDANCE TO THE PLANNING
AND ZONING COMMISSION ON ELEMENTS TO BE INCLUDED IN
THE DEVELOPMENT OF STANDARDS FOR MANUFACTURED
HOUSING
WHEREAS, the City Council has held Policy Development/Review Workshops, on
May 14, 1996 and on July 9, 1996 to discuss the development of standards for manufactured
housing to be included in the Zoning Ordinance and Subdivision Regulations; and
WHEREAS, the Planning and Zoning Commission considered standards for lot size
(density) and street width on July 2, 1996; and
WHEREAS, the City Council has requested that the Planning and Zoning Commission
develop a complete set of standards for manufactured housing;
NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE
CITY OF GEORGETOWN, TEXAS, THAT:
SECTION 1. The facts and recitations contained in the preamble of this resolution are
hereby found and declared to be true and correct, and are incorporated by reference herein and
expressly made a part hereof, as if copied verbatim. The City Council hereby finds that this
resolution implements the following Policies of the Century Plan - Policy Plan Element:
1. Housing Policy 1 which states: "The City, builders, developers and property
owners provide safe and adequate housing opportunities for all household types"; and
2. Growth and Physical Development Policy 2, which states: "The City's regulations
implement the policy statements and provide the opportunity to seek change with
reasonable effort and expense";
and further finds that the adoption of this resolution is not inconsistent or in conflict with any
other Century Plan Policies, as required by Section 2.03 of the Administrative Chapter of the
Policy Plan.
SECTION 2. The City Council instructs the Planning and Zoning Commission to include
the following elements in the standards being developed for manufactured housing: (1) minimum
space size for each house shall be 3,500 square feet; (2) the width of interior drives shall be a
minimum of 28 feet; (3) all interior drives be open to the public; and (4) two points of ingress
and egress be provided to insure adequate emergency access.
Resolution No. 7`60 0 6' / 1 ZV
Page 1 of 1
SECTION 3. This resolution shall be effective immediately upon adoption.
//A
RESOLVED this'kl day of July, 1996.
ATT T: THE CITY OF
F GEORGE OWN:
Sandra D. Lee By: EO WOOD
City Secretary Mayor
APPROVED AS TO FORM:
cz_.'ice
.Marianne Landers Banks
City Attorney
Resolution No.
Page 1 of 1
Exhibit A
City Council Recommended Manufactured Home Park Development Standards
1. Minimum Development Parcel
Size, Dimension. Maximum
Impervious Coverage, Building
Coverage
2. Lease Space Setbacks/Minimum Dimensions
3. Parking
4.
Landscaping/Open
Space
5. Sidewalks and accessory
storage
5 acres
25' front
2 spaces per unit.
20% of parcel area +
No additional requirement for sidewalks
100' width, 120' depth
20' rear (or 10' next to commercial or industrial)
This standards is currently required for all residential uses.
applicable bufferyard.
unless street standards are not met.
50% impervious cover
15' side(building seperation, no minimum setback per lease space side)*
As with all other uses, parking must be located behind the
This standard is currently
Current public street standards only requirt /
35% building cover
No minimum lease space size provided setbacks are met
front building line of each lot/lease space.
required for Multifamily
sidewalks w/in 1,000 feet of schools or park
These standards, except for parcel size, are the
These standards are primarily the same as the current Multifamily standards.
Additional common parking areas built to accommodate
development.
property for local streets. There is not a
same as our current Multifamily standards and will
* However, a provision allowing zero side lot/space line siting in order to
guest parking, recreational vehicle parking, etc. are not
Park land dedication will be
separate, on-site sidewalk requirement for
be applied on a parcel wide basis, not lease space
maximize usable open space on what will probably be smaller lots than other
currently required for other residential development, so it is
required as is currently the
Multifamily developments.
by lease space basis.
single family detached uses are required to have.
not recommend for this use.
case for all residential
No additional/lessened requirement for
The parcel size is larger than that required for
No minimum individual lease space size, width or depth standards are necessary if
However, if street width standards are not required to be met
development.
accessory structures.
Multifamily because the manufactured home park
the setback standards are met due to the standardized width of the manufactured
and no on -street parking will be allowed, then a common use
Accessory structures on permanent foundations
use requires greater land area to accommodate
home, which is limited to 18' due to transport concerns.
parking area of 1 space per 4 units should be required.
I
must meet the lease space setback requirements
even a small number of units to make it a viable
that are currenity in place for other residential
commercial development.
uses.
6. Skirting
7. Foundation/Tie down
S. Meet HUD Code Construction Standards,
height standards
9. Individual meters
10. Public or Private
Streets/ Integrated or not
with other public streets
Skirting that is
All first time installations must meet the manufacturers instructions for installation and
Any manufactured home installed within a manufactured home
Must be individually metered.
Open to the public and built to
complementary to building
all installations must meet State standards and be performed by a licensed installer.
park developed under the Subdivision Regulations must meet the
Currently, Multifamily units have
public standards (minimum of 28' of
exterior if "ground set"
The State inspects all licensed installations, so the City does not have to make an inspection
HUD construction code standards.
individual meters and customers are
pavement curb to curb) with at least
foundations are not
other than those for plumbing and mechanical hook-ups to the manufactured home units.
Height limit of 40'.
charged for utility usage individually.
two entrances and exits. If the
utilized.
However, because the Building Code does have requirements regarding manufactured home
The RM -2 District zoning restricts building height to 40'. The
The same standard should apply to this
developer chooses to gate the
installation, for those installations that are made within the City limits, the City will make
Subdivision Regulations, which will effect any development outside the
use because it encourages individual
streets, they cannot be classified as
and inspection, in addition to the State's inspection.
City limits, regulates height by requiring an increased side and rear
conservation and ensures proper billing
public and the gates can only be
The State standards and manufacturers standards do not require that the lowest profile
setback if the structure is above 35' when located adjacent to
to individual users.
closed between the hours of 10 p.m.
installation be utilized. If a low profile method were to be by the City it would mean that
commercial and above 20' when located next to residential.
and 6 a.m. Any gate must meet
special grading would have to be down at each lease space in order to accomodate access to
emergency services personnel
the underside of the manufactured home unit. The additional cost would be significant.
I
approval prior to installation