Loading...
HomeMy WebLinkAboutORD 2007-32 - REZ Estrellea Mixed UseORDINANCE 0. OrdinanceAn of • of of •r•-•wn, Texas, amending part of Zoning District Map adopted on the 41hDay of April 2002 in accordance with the Unified Development • passed and.•,r •• on D, of it to Change 15.16 acres out Williamsonof the David Wright Surve 11 Oakland Hills, L.P. as recorded in Document No. 2004099368 of the Official Records of • from AG, Agriculture to PUD, Planned Unit Development Base Zoningof ammerciaL* repealing conflictingordinances and o • mcluding a severability clause; and establishing an effective date. Whereas, an application has been made to the City Council for the Purpose of changing the Zoning District Classification of the following described real property ('The Property"): 15.16 acres out of the David Wright Survey, Abstract No. 13, being a portion of the 86.153 acre tract conveyed to Oakland Hills, L.P. as recorded in Document No. 2004099368 of the Official Records of Williamson County, Texas, hereinafter referred to as 'The Property"; Whereas, the City Council has submitted the proposed change in the Base Ordinance to the Planning and Zoning Commission for its consideration in a public hearing and for its recommendation or report; and Whereas, notice of such hearing was published in a newspaper of general circulation in the City; which stated the time and place of hearing, which time was not earlier than fifteen (15) days for the first day of such publication; and Whereas, written notice was given not less than fifteen (15) days before the date set for the meeting before the Planning and Zoning Commission to all the owners of the lots within two hundred feet of the property, as required by law; and Whereas, the applicant for such zoning change placed on the property such sign(s) as required by law for advertising the Planning and Zoning Commission hearing, not less than fifteen (15) days before the date set for such hearing; and Whereas, the City Planning and Zoning Commission in a meeting held on April 3, 2007 recommended Approval of the requested zoning change for the above described property from AG, Agriculture to PUD, Planned Unit Development with a Base Zoning District of C-1, Local Commercial. III Fill Jill 11;11111�111111 Section 1. The facts and recitations contained in the preamble of this ordinance are hereby found and declared to be true and correct, and are incorporated by reference herein and expressly made a part hereof, as if copied verbatim. The City Council hereby finds that this ordinance implements the following objective of the Georgetown Century Plan, Future Land Use and Thoroughfare Plan: • Objective 1.3: Ensure that new developments will be compatible with existing land uses in terms of use, density, building heights, scale, and offsite effects. • Objective 1.5: Require zoning change requests to be consistent with the Future Land Use Plan. - The proposed PUD, Planned Unit Development district is consistent with, and implements, the "Mixed Use" land use designation. and further finds that the enactment of this ordinance is not inconsistent or in conflict with any other Century Plan Policies, as required by Section 2.03 of the Administrative Chapter of the Policy Plan, Section 2. The Base Ordinance and the Zoning Map of the City, as well as the Zoning District for the Property shall be and the same is hereby changed from AG, Agriculture to PUD, Planned Unit Development with a Base Zoning District of G1, Local Commercial., in accordance with the Development Plan which is attached hereto as Attachment A and incorporated by reference herein, is hereby adopted by the City Council of the City of Georgetown, Texas, Section 3. All ordinances and resolutions, or parts of ordinances and resolutions, in conflict with this Ordinance are hereby repealed, and are no longer of any force and effect Section 4. If any provision of this Ordinance or application thereof to any person or circumstance, shall be held invalid, such invalidity shall not affect the other provisions, or application thereof, of this Ordinance which can be given effect without the invalid provision or application, and to this end the provisions of this Ordinance are hereby declared to be severable. Section 5. The Mayor is hereby authorized to sign this Ordinance and the City Secretary to attest. This Ordinance shall become effective and be in full force and effect on the date of final adoption by City Council. PASSED AND APPROVED on First Reading on the24th day of April 2007. j � PASSED AND APPROVED on Second Reading on theh day of May 2007. ATTEST: ,1 Sandra D. Lee City Secretary APPROVED AS TO FORM: Patricia E. Carls City Attorney J: \ CUR_PLAN \ REZONE \ REPORT \ 2007\ Estrella.ord.doc THE CITY OF GEORGETOWN: Am • PlannedUnitDevelopment Development A. Purpose and Intent The Estrella Mixed Use PUD is composed of approximately 15 acres, as described in Exhibit B (Legal Description). The development of this property is planned as a high quality, mixed use center with a blend of retail, office and residential opportunities. A development plan has been attached to this PUD, Exhibit C, to illustrate the design intent for the property. The development plan is conceptual and depicts residential townhomes or condos on the eastern half of the property and a mix of professional office and retail on the western portion. The proposed buildings will be composed of a mix of one and two story buildings with retail uses facing William's Drive and professional office users located behind the retail. The office and retail buildings have been configured to define a central pedestrian corridor and plaza space, which will act as an amenity for future employees, residents and visitors. The central pedestrian corridor has been aligned with the entry to the residential portion of the development to encourage walking and the potential for a "live/work" relationship. Be Applicability and Base Zoning All aspects regarding the development of this PUD shall comply with the 2006 version of the Georgetown Unified Development Code, except as established in this exhibit, titled Exhibit A. Unless modified within this PUD document, the development standards defined for the zoning category C-1 shall apply. In the event of a conflict between this PUD and the base zoning of C-1 defined in the 2006 Unified Development Code, this PUD shall control. CO Site Plan Implementation of this PUD development plan will be reviewed pursuant to a site plan as required by UDC Section 3.09. Said site plan will graphically depict compliance with all development standards of this PUD, as well as the underlying C-1 zoning district, including landscaping as required pursuant to UDC Chapter 8 ("Landscaping and Buffering") . Estrella Development Plan AG to PUD Page 1 of 5 ORb. 9,001*ee 324 D. Conceptual Development Plan Exhibit C attached is a conceptual development plan intended to visually convey the design intent for the Estrella site. The final building and parking configurations are not final, and are subject to refinement at the site planning stage. This PUD zoning document does not constitute site plan approval of the attached plan. The development plan has been designed to allow a mix of uses from retail and office to residential townhomes and condominiums. The intent of the plan is to create a central courtyard defined by the buildings. A strong pedestrian axis, which is aligned with the residential portion of the site, has been incorporated to emphasize the pedestrian environment and encourage walking between the mixed uses. Due to the numerous trees on site, the buildings and parking areas will be adjusted to preserve as many existing trees as possible within the plan, thus creating a more attractive, hill country setting. The driveway access points have been coordinated with the adjacent Wesleyan facility located to the west. The internal roadway system has been designed to allow future connection to the adjacent property to the east. In order to ensure a mix of uses on the Estrella site, the following criteria are established as minimum requirements. ♦ Retail: Minimum of 15,000 square feet ♦ Office: Minimum of 20,000 square feet ♦ Residential: Minimum of 7 acres D. allowable Uses The uses allowed for the Estrella Mixed Use development shall comply with the list of allowed and prohibited uses defined in the Georgetown UDC Zoning Use Table 5.01.030, under the zoning category of C-1, with the addition of the following uses: ♦ Single Family Attached Condominiums E. Pedestrian Circulation Pedestrian circulation will be a vital component of the conceptual development plan to encourage an alternative mode of transportation within the mixed use development. In cases where the front building fagades face Williams Drive, a sidewalk shall be located between the front fagade and the Williams Drive right of way. The general location is illustrated along the front of the residential units on the conceptual development plan, Exhibit C. In areas where the parking facilities are located between the right of way and the buildings, the sidewalk may be routed internally to provide the pedestrian connection along the front of the buildings. The internalized walkways must be connected to the �- .. AG to PUD Paore 2 of .. A_ o . residential walkway system in an organized and logical circulation pattern for easy access between the uses. As illustrated on the conceptual development plan, a central pedestrian corridor will be created to connect the Estella Crossing roadway to the residential portion of the development. If any modifications occur to the conceptual development plan during the site plan process, this pedestrian connection will be maintained in some form to ensure pedestrian connectivity between the retail/office uses and the residential units. F. Architectural Criteria Once the design of the development is refined and finalized during the site plan review process with the City, a comprehensive architectural theme will be developed which will specify the architectural theme, materials and colors for the development. In order to convey the architectural theme, items such as architectural elevations, material sample boards and color samples shall be submitted to the City in conjunction with the site plan review process. G. Signage A master sign plan shall be prepared for the mixed use development prior to the issuance of any sign permits. The intent of the development will be to create a master sign package which will have a common theme, material palette and appearance which will visually relate to the architecture and tie the various land uses together. The proposed conceptual sign types and locations for the project are as follows: One (1) freestanding monument sign at the proposed entry road from Williams Drive, which bisects the property between the residential and office/retail uses One (1) Multi Tenant Sign, designed per Section 10.06.050, F, 2 One (1) freestanding monument sign at the proposed site entry from Estrella Crossing, across from building 3 on the conceptual development plan, Exhibit C One (1) freestanding, internal monument sign at the entry drive which leads to the residential enclave on the eastern portion of the site Sign dimension criteria shall comply with Section 10.06, Sign Design and Area Regulations and Table 10.06.010, C-1 District. The intent of this development is to create a master sign package which stays within the maximum square footage allowance of the UDC, but which allows the transfer of square footage between sign type classifications. Estrella Development Plan AG to PUD H. Development Standards The Estrella Development will comply with the Development Standards set forth under the base zoning district of C-1, with the exception of the following modifications: 1. "Build to" tine provision: Per the Unified Development Code, table 6.03.020, Non Residential Lot and Dimensional Standards, the required Front Build to Line minimum percentage is 15%. For the purpose of this Estrella PUD, the required "Front Build -to line minimum" provision shall be applied by evaluating the entire Estrella site frontage along Williams Drive. Regarding the "build -to" requirement, the Estrella site and the multiple buildings shall be evaluated as one development. For the entire Estrella Mixed Use Development site, a minimum of 30% of the entire site's frontage on Williams Drive shall be faced by a primary architectural facade located within five feet of the required Scenic Gateway Corridor buffer. No parking spaces will be allowed within this 30% frontage. Sidewalks, access drives, berms, retaining walls and landscaping are allowed between the building facade and the Williams Drive right of way. 2. Scenic Gateway Corridor The Estrella Mixed Use tract is located within the Williams Drive Corridor, which is designated as a Scenic/Natural Gateway by the Georgetown Unified Development Code, Section 8.07.020, B. The Estrella development will comply with the required 25' gateway landscape buffer and planting requirements defined by section 8.07.050 of the Georgetown Unified Development Code. 3. Impervious Cover The Estrella Mixed Use site is located over the Edwards Aquifer. Per the Georgetown Unified Development Code, Section 11.02, the impervious cover limit is established at 50% with the potential for increases up to 65% with waiver criteria. The impervious cover maximum for the Estrella Mixed Use site shall be 60%. The calculation of the Estrella Mixed Use site impervious cover shall be measured as a whole based upon the entire 15.16 acres. The following measures will be incorporated into the site design to justify the overall impervious cover increase: ® Parking lot design configured to preserve existing trees within islands and parking lot medians and parking areas separated by planted or natural landscaping features. Per UDC Section 11.02.020, A, 2, a 5% impervious cover waiver is allowed if the development provides a parking lot design that breaks up the parking area into areas separated by planted or natural landscaping features. The plan will exceed the City of Georgetown landscaping minimum requirements by at least 30%. Per UDC Section 11.02.020, A, 4, an impervious cover waiver of 3% is allowed for Over Provision of Landscaping by 30%. Low impact site design measures such as, but not limited to, bio swales, grassed filter strips and bio retention facilities will be incorporated into the design. Per UDC Section 11.02.020, A, 1, an impervious cover waiver of 7% for Low Impact Site Design is allowed. 4. Building Height The Estrella Mixed Use site is composed of office, retail and residential uses. Certain buildings within the development will be up to two stories and will vary in height. Per the UDC Section 6.03.020, Non Residential Dimensional Standards, the maximum building height in the C-1 zoning district is 35'. In order to account for architectural design features and flexibility in the design of the mixed use buildings, the proposed maximum building height shall be 45' for the Estrella Mixed Use site. Estrella Development Plan AG to PUD W- JLC' r �m 0 O nva N - O i » R c m s ffi omL li d r E�c'u LL N > m U c6 JLC' Z W ^2 n O 1.1.1 U3 W z ® p 111 LU z O ®w h. O U) IY W �m Y nva - o E m o y » R c m s ffi omL o r E�c'u _ > m O � c c ffiBE U e - E E o 0 V Q $ m m a m `m amo- E�-m gym 'o b W Z W ^2 n O 1.1.1 U3 W z ® p 111 LU z O ®w h. O U) IY W Y N O � U e V U W